SURGICAL
hamburger
product photo

HIGHEST MOLECULAR WEIGHT COHESIVE IN THE HEALON® FAMILY OF OVDs

HEALON GV® OVDs offer high viscosity for deep anterior chamber creation and maximum space for maneuverability with minimal damage to the cornea or other delicate ocular tissues.

POWERFUL PROTECTION

Compared to Alcon’s VISCOAT and Bausch & Lomb’s Ocucoat OVDs,* the HEALON GV® OVD produced considerably less endothelial cell loss.1

HEALON GV® OVD

Classification

Cohesive

Product Volume

0.55 and 0.85 mL

Viscosity

2,500,000 cps

Composition

1.4% sodium hyaluronate

Molecular Weight

5,000,000 Da

FOOTNOTES

*VISCOAT is a trademark of Novartis International AG; Ocucoat is a trademark of Bausch & Lomb Inc.

REFERENCES

  1. Holzer MP, Tetz MR, Auffarth GU,Welt R, Volcker HE. Effect of Healon5 and 4 other viscoelastic substances on intraocular pressure and endothelium after cataract surgery. J Cataract Refract Surg.2001;27(2):213-218.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE HEALON GV® OPHTHALMIC VISCOELASTIC DEVICE

CAUTION

Federal law restricts this device to sale, distribution and use by or on the order of a physician.

INDICATIONS

The HEALON GV® OVD is indicated for use in anterior segment ophthalmic surgical procedures. The HEALON GV® OVD creates and maintains a deep anterior chamber, to facilitate manipulation inside the eye with reduced trauma to the corneal endothelium and other ocular tissues. The HEALON GV® OVD also can be used to efficiently maneuver, separate and control ocular tissues.

CONTRAINDICATIONS

There are no known contraindications to the use of the HEALON GV® OVD when used as recommended.

PRECAUTIONS

Precautions normally considered during ophthalmic surgical procedures should be taken. Postoperative intraocular pressure may be increased if the HEALON GV® OVD is left in the eye. Due to the greater viscosity of the HEALON GV® OVD, this increase in postoperative IOP may be higher than that caused by leaving the same amount of other sodium hyaluronate viscoelastic products, with lower zero shear viscosity, in the anterior chamber. Since rises in postoperative intraocular pressure, including cases of significant elevation and subsequent complications, have been reported, the following precautions are strongly recommended: Special care should be taken to ensure as complete removal as possible by continuing to irrigate/aspirate after you see displacement of the initial bolus of viscoelastic from the eye, continued irrigation/aspiration should facilitate removal of viscoelastic which may remain in the anterior segment. Pre-existing glaucoma, other causes of compromised outflow, higher preoperative intraocular pressure and complications in surgical procedures also may lead to increased intraocular pressure, consequently, extra care should be taken in patients with these conditions. Carefully monitor intraocular pressure, particularly during the early postoperative period. Treat with appropriate intraocular pressure lowering therapy, if required. The HEALON GV® OVD is a highly purified fraction extracted from avian tissues which may contain minute amounts of protein. The potential risks associated with the injection of biological material should be considered. Express a small amount of the HEALON GV® OVD from the syringe prior to use and carefully examine it during use to avoid injecting minute rubber particles which may be released when the syringe diaphragm is punctured. Sodium hyaluronate solution may appear cloudy or form precipitates when it is injected. Based on in vitro laboratory studies, this phenomenon may be related to interactions with concomitantly used ophthalmic medications or detergents which remain in reused cannulas. Reprocessed cannulas should not be used. Sporadic reports have been received indicating that the HEALON® OVD may become ”cloudy” or form a slight precipitate following instillation into the eye. The clinical significance of these reports, if any, is not known since the majority received to date do not indicate any harmful effects on ocular tissues. The physician should be aware of this phenomenon and, should it be observed, remove the cloudy or precipitated material by irrigation and/or aspiration. In vitro laboratory studies suggest that this phenomenon may be related to interactions with certain concomitantly administered ophthalmic medications. Use only if solution is clear.

ADVERSE EVENTS

Increased intraocular pressure has been reported after use of the HEALON GV® OVD. Increased intraocular pressure is likely to occur if the HEALON GV® OVD is not removed as completely as possible. Clinical judgement concerning the use of this product should be considered in cases where thorough removal may not be possible. The Precautions noted above should be taken to manage any increased postoperative intraocular pressure and to reduce the likelihood of occurrence of related postoperative complications such as optic neuropathy, pupillary atonia and dilation, and iris atrophy. Rarely, postoperative inflammatory reactions (iritis, hypopyon, endophthalmitis) following the use of sodium hyaluronate, as well as incidents of corneal edema and corneal decompensation, have been reported. Their relationship to sodium hyaluronate has not been established.

ATTENTION

Reference the Directions for Use for a complete listing of indications, warnings, and precautions.

PP2017MLT0317

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2017 Abbott Laboratories Inc. Abbott Park, Illinois, USA. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. All other trademarks are the intellectual property of their respective owners.

accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?